Skip to main content
Home / Products / Coolant Glycol Antifreeze / Antifreeze Coolant Liquid

Antifreeze Coolant Liquid

Antifreeze Coolant Liquid
Coolant Glycol Antifreeze
Product code  RXSOL-16-4020-020

Antifreeze compound for cooling water systems , It is a Very effective blend of GLYCOL classified chemicals along with CORROSION inhibitor to protects all engineering precious metal including aluminium . Its chemically treated layer protect radiators

Same-day UAE delivery Bulk & custom packaging Technical support included

Product Description

RXSOL ANTIFREEZE Corrosion Inhibitor

Introduction

Antifreeze compound for cooling water systems , It is a Very effective blend of GLYCOL classified chemicals along with CORROSION inhibitor to protects all engineering precious metal including aluminium . Its chemically treated layer protect radiators and engines, against rust and corrosion. Its proper dose in cooling system gives full protection from corrosion.

It is biodegradable and does not present an environmental problem.


 


 

Application & Usage

Solution Strength :
25 Ltrs RXSOL-16-4020-020 : 75 Ltrs Water gives freezing protection up to -140C  "or" 25% solution (1 part anti-freeze to 3 parts water)
For extra cold / winter climate , increase to a 33% solution (1 part anti-freeze to 2 parts water) to give freezing protection down to -170C.

 


 

Dosage

EYES : Irrigate copiously with clean, fresh water for at least 15  minutes. Seek medical advice.
SKIN :  Wash  immediately  with  plenty  of  water.  Remove  contaminated   clothing.  If  irritation  persists  seek  medical attention.  Wash  contaminated  clothing  before  using  them.
INHALATION : Remove to fresh air. If breathing is irregular seek medical advice.
INGESTION :  Obtain  immediate  medical  attention.  Induce  vomiting  only  if indicated  by  the  doctor.  Never  give anything  by  mouth  to  an  unconscious  person.

 

Useful Area

MAXIMUM PROTECTION UNDER WIDE OPERATING TEMPERATURE RANGE
 
Fully formulated ethylene glycol base Coolant that has improved heat transfer ability.
Organic Acid Technology providing superior corrosion and rust protection leading to reduced maintenance.
Meets industry leading specifications – JIS K 2234 Class 2, ASTM D3306, BS 6580:2010.

Industrial Area

RXSOL branding, present  a Heavy-Duty Glycol Antifreeze Coolant. One correction: (CH₂OH)₂ is not the proper formula for ethylene glycol; use C₂H₆O₂ / HOCH₂CH₂OH. Also, because your stated glycol content is only 40–50%, it should be positioned as a formulated/prediluted coolant rather than a glycol concentrate. ASTM D6210 specifically covers fully formulated glycol-based coolants for heavy-duty engines and recognizes prediluted ethylene-glycol coolants at 50 vol% minimum. 

RXSOL HEAVY-DUTY ANTIFREEZE COOLANT

Brand: RXSOL
Product Name: RXSOL Heavy-Duty Antifreeze Coolant
Chemical Name: Ethylene Glycol Based Engine Coolant
Grade: Heavy-Duty Antifreeze / Coolant
Base Chemical: Mono Ethylene Glycol (MEG)
Molecular Formula of Glycol: C₂H₆O₂
Chemical Structure: HOCH₂CH₂OH
Glycol Content: 40–50%
Form: Liquid

DESCRIPTION

RXSOL Heavy-Duty Antifreeze Coolant is an ethylene glycol-based cooling fluid formulated for use in heavy-duty engine and industrial cooling systems.

The product contains 40–50% glycol together with water and a corrosion-inhibitor/additive package designed to provide effective heat transfer while helping protect cooling-system components against corrosion, rust, scale formation and temperature-related damage.

RXSOL Heavy-Duty Antifreeze Coolant provides year-round cooling-system protection and is particularly suitable for heavy-duty diesel engines, generators, construction equipment, marine engines and other closed-circuit cooling systems, subject to equipment-manufacturer recommendations.

SPECIAL FEATURES

  • Ethylene glycol-based heavy-duty coolant

  • 40–50% glycol content

  • Provides antifreeze and coolant protection

  • Helps increase boiling and reduce freezing protection limits compared with plain water

  • Excellent heat-transfer characteristics

  • Helps protect against rust and corrosion

  • Helps control scale and deposit formation

  • Protects cooling-system metal surfaces

  • Suitable for heavy-duty operating conditions

  • Suitable for year-round cooling-system service

  • Ready and easy to use

  • Helps extend cooling-system component life

APPLICATION

RXSOL Heavy-Duty Antifreeze Coolant is recommended for cooling systems used in:

  • Heavy-duty diesel engines

  • Marine diesel engines

  • Trucks and commercial vehicles

  • Diesel generator sets

  • Construction equipment

  • Earth-moving machinery

  • Mining equipment

  • Agricultural machinery

  • Industrial engines

  • Compressors

  • Stationary engines

  • Closed-loop cooling systems

COMPOSITION

Component Composition
Mono Ethylene Glycol 40–50%
Corrosion Inhibitor / Coolant Additive Package Proprietary
Demineralized Water Balance
Dye As required

TYPICAL PROPERTIES

Property Typical Specification
Appearance Clear coloured liquid
Chemical Base Mono Ethylene Glycol
Glycol Content 40–50%
Form Liquid
Solubility in Water Completely miscible
Odour Mild / characteristic
Specific Gravity Approx. 1.06–1.08 at 20°C*
pH Typically alkaline, depending on inhibitor package*
Molecular Formula of MEG C₂H₆O₂
Molecular Weight of MEG 62.07 g/mol

*Final values should be confirmed from QC testing of the actual manufactured formulation.

PERFORMANCE BENEFITS

FREEZE PROTECTION
The glycol component lowers the freezing point of the cooling fluid and provides protection under low-temperature operating conditions.

HIGH-TEMPERATURE PROTECTION
Raises the boiling point relative to plain water and assists reliable operation at elevated cooling-system temperatures.

CORROSION PROTECTION
Contains an inhibitor package designed to protect compatible metals within the cooling circuit against corrosion.

EFFICIENT HEAT TRANSFER
Provides effective transfer of heat from engine components to the radiator or heat exchanger.

HEAVY-DUTY PERFORMANCE
Designed for demanding engine and industrial cooling applications where continuous temperature control and corrosion protection are required.

DIRECTIONS FOR USE

Where supplied as a 40–50% glycol ready-to-use coolant, RXSOL Heavy-Duty Antifreeze Coolant should normally be charged directly into a clean cooling system without additional dilution, subject to the required freeze protection and engine manufacturer's instructions.

Before filling:

  1. Drain the old coolant completely.

  2. Flush contaminated cooling systems where necessary.

  3. Check hoses, seals and connections for leakage.

  4. Fill with RXSOL Heavy-Duty Antifreeze Coolant.

  5. Remove trapped air according to the equipment manufacturer's procedure.

  6. Run the system and check coolant level after circulation.

  7. Top up with compatible coolant as required.

Do not mix different coolant technologies unless their compatibility has been established.

IMPORTANT

The exact freeze point, boiling point, corrosion performance and compliance with ASTM D6210/D3306 or individual OEM specifications must be established by laboratory testing of the finished product.

ASTM or OEM compliance should not be printed on the RXSOL label/TDS solely on the basis of glycol concentration.

STORAGE & HANDLING

Store in a cool, dry and well-ventilated area in tightly closed original containers.

Avoid contamination with oils, fuels, acids, incompatible coolants or other chemicals.

Ethylene glycol is harmful if swallowed. Avoid ingestion and unnecessary skin or eye contact. Keep away from children and animals.

Refer to the RXSOL Safety Data Sheet before handling.


RXSOL HEAVY-DUTY ANTIFREEZE COOLANT
Ethylene Glycol Based • 40–50% Glycol • Heavy-Duty Cooling System Protection

 

 
Helps to avoid engine extreme temperatures. RXSOL ANTIFREEZE contains special anti-freeze and anti-rust additives.
 
An antifreeze is an additive which lowers the freezing point of a water-based liquid
 
Chemical stable Low Viscosity
Longer Life, Less corrosive to the metal parts & less changes
Highly effective in heat transfer
Low Freezing point & High Boiling point
Keep the engine cool & prevent the over heating
Improve the air conditioner output.
Less Scale formation & degrading
Enhance fuel performance.

#Coolant_MuscatOman
#Coolant_UnitedArabEmirates
#Coolant_ManufacturerSupplier
#Coolant_MumbaiKolkataChennaiVisakhapatnamSuratGandhidham

Remarks / Precautions

Antifreeze

APPLICATIONS

Antifreeze Special is free from amine, phosphate and nitrite etc. And uses as  engine Antifreeze as well as coolant. This product is based on ethylene glycol. It contains a corrosion inhibitor,  salts of organic acids and silicates (Si-OAT). It protects all metallic parts against corrosion and deposits in the cooling system.

Benefit

The product protects all parts of cooling system from frost, oxidation and overheating.

It has long-term protection against corrosion for all materials used in the engine and radiator construction, such as cast iron, aluminium, copper and solder alloys as well as a good compatibility with hoses, seals or plastics.

It contains carefully selected amine, nitrite, boron and phosphate free inhibitors and is therefore environmentally friendly.

Notes

SMART TECHNOLOGY COOLANT

Specialized coolant formulation containing organic compounds and superior corrosion protection. It is particularly effective in preventing cavitation and pitting in high-speed coolant pumps with aluminum housings and impellers. This advanced blend enhances system reliability and extends equipment life. Ideal for industrial engines, DG sets, and other high-performance cooling systems. Designed for long-term metal protection and thermal efficiency.

  • Contains Multi-Metal corrosion inhibitors – guards against cavitation corrosion
  • Extends pump life – especially in aluminum housing systems
  • Organic-based formula – efficient and long-lasting protection
  • Ideal for high-speed coolant pumps – marine, industrial, or DG sets
  • Enhances thermal efficiency – stable under extreme conditions
  • Helps maintain system reliability – reduces downtime and damage

Packing Sizes

5, 20 ltr, 35, 50, 210 ltr and also in IBC TANK. mail us for factory sale discounted price.

Material Safety Data Sheet (MSDS)

Product Name : RXSOL-16-4020-020
Product Type : ANTIFREEZING LIQUID

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point ::: Mumbai, Kandla, Kolkata, Visakhapatnam, Chennai, Fujairah, Muscat, Nairobi

Phone : +91 22  27815540 / 41 / 42
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

Blend of Glycol, Ethanediol & Corrosion Inhibitor  

50-60

107-21-1

203-473-3       

R-22

 603-027-00-1

Di-Sodium Sebacate 4-5 17265-14-4 241-300-3 --- ---
Benzotriazole 0.25 - 0.30 95-14-7 202-394-1 R-43 ---

*See Section 16

3.1  Substance/Preparation  Classification: This preparation  is dangerous  under  67/548/EEC  and  1999/45/EC  regulations  and  subsequent  amendments.  This preparate  requires  a  safety  data  sheet  according  to  the  91/155/EC  regulation  and  subsequent  amendments.  Further information on health and/or environmental hazards can be found in sections 11 and 12 of this sheet.Danger Symbols: Xn Phrases R: 22 3.2  Danger  Identification HARMFUL IF SWALLOWED

 

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes.Seek medical advice 

Ingestion

Never give anything by mouth to an unconscious person. Give plenty of water to drink. Seek medical advice if necessary

Inhalation

Vapours or aerosols may cause irritation of eyes, nose and respiratory tract. Remove patient to fresh air

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45)

-  Carbon oxides may be formed
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

 

Personal Precautions

Wear protective clothing as per section 8.

Environmental Precautions

No special precautions are required for this product.

Immediate Actions

Shut off source of leak if safe to do so.

Clean Up Actions

Absorb spillage in suitable inert material.Flush spill area with copious amounts of water.

Special Precautions

Wear protective clothing as per section 8.

 

Handling

The usual precautions for handling chemicals should be observed. Eyewash bottles should be available

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49). Protect from frost

 

 Exposure Limits

There are no recommended or established controls for this product

 Exposure controls

No special ventilation is required unless the product is used in a spray form

Occupational exposure controls

No respiratory protection is required unless subject to contact with substance mist. Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended

Odour

Characteristic

Appearance

Liquid,  soluble in water

pH

7.5 at 100 % concentration

Boiling point

150

Vapour  density

N.A

Melting point

36iC

Completely soluble in water

Specific gravity (water=1)

1.15

Non combustible

The product is stable in normal conditions of use and storage. Due to thermal decomposition or in  the  event  of  a  fire vapours  may  be  produced  potentially  dangerous  to  health.Ethylene glycol may absorb moisture from the atmosphere up to twice its own weight.

 

Acute  effects

ingestion  of  this  product  is harmful.  Even   small  amounts  of  product  may cause  serious  health problems  (stomach  pain,  nausea,  sickness,  diarrhoea,  etc.).  This  product  may  slightly  irritate  mucosas,  the  upper. respiratory  tract,  eyes,  and  skin.  Exposure  symptoms  may include:  sting,  cough,  asthma,  laryngitis,  respiratory. disorders,  headache,  nausea  and  sickness

Ethylene  glycol

following  ingestion  it initially  stimulates  the  CNS;  later  on  depression  results.  Renal  damage  with anuria  and  uremia  may occur.   Symptoms  of  over  exposure  are:  vomiting,  somnolence,  difficulty  in   breathing,convulsions. The lethal dose in man is approximately 1.4 l/kg. The route of entry is inhalation and ingestion.

Use this  product  according  to  good  working  practices.  Avoid  litter.  Inform  the  competent  authorities,  should  the product reach waterways or sewers or contaminate soil or vegetation. Ethylene  glycol  is  biodegradable

Consider  the  possibility  of  burning  the  product  in  a  suitable  inceneritor.   Acid  or  basic  products  must  always  be neutralized  before  undergoing  any   treatment,  including  biological  treatment  whenever  feasible.  If   the  waste  is solid,it can be disposed of in a landfill.

This substance is not dangerous under current provisions of the Code of International Carriage of  Dangerous  Goods by  Road  (ADR)  and  by  Rail  (RID),  of  the  International  Maritime  Dangerous  Goods  Code  (IMDG),  and  of  the International Air Transport Association (IATA) regulations.

R-22 HARMFUL IF SWALLOWED Danger  labelling  under  regulations  67/548/CEE  and  1999/45/CE  and  following  amendments  and  adjustments.Workers exposed to this chemical agent must undergo health checks according to regulation 98/24/CE.

R22 HARMFUL IF SWALLOWED.
GENERAL BIBLIOGRAPHY
1. Regulation 1999/45/CE and following amendments;
2. Regulation 67/548/CEE and following amendments and adjustments (technical adjustment XXVIII);
3. Regulation 91/155/CEE and following amendments;
4. The Merck Index. - 10th Edition;
5. Handling Chemical Safety;
6. Niosh - Registry of Toxic Effects of Chemical Substances;
7. INRS - Fiche Toxicologique (Toxicological sheet);
8. Patty - Industrial Hygiene and Toxicology;
9. N.I. Sax-Dangerous properties of Industrial Materials-7, 1989 Edition.
Note for users:The information contained in the present sheet are based on our own knowledge on the date of the
last version.Users must verify the suitability and thoroughness of provided information according to each specific use of the Product.This document must not de regarded as a guarantee on any specific product property.The use of this product is not subject to our direct control; therefore, users must, under their own responsibility,comply with the current health and safety laws and regulations. The producer is relieved from any liability arising from improper uses.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Supply Locations

Antifreeze Coolant Liquid Manufacturer, Exporter and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Gandhidham, Fujairah, Abudhabi, Dubai, Sharjah, UAE Middle East Gulf, Muscat Barka Sohar Oman, Kenya Nairobi Uganda Africa, Canada

Need pricing or a bulk quote?

Send us the product and quantity — our team replies with a quote same day.

WhatsApp Us